ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Campaign - Defective Blower Switch or Resistor|Page 8558 > < Campaign - Defective Blower Switch or Resistor|Page 8556
Page 9
background image

D.

Strip 1/4-inch insulation from the selected wires.

E.

Install the appropriate splice connector using Crimp Tool # AD1522 or equivalent ratchet action crimp tool.

F.

Test the integrity of all splices after crimping. Grasp the wires at each splice and pull gently. If any wire is not attached securely, replace the
splice connector and crimp firmly.

G.

Repeat steps B through F for the remaining wires, one at a time.

H.

Heat each splice connector thoroughly until the tubing shrinks and adhesive flows from each end. Use Rotunda Heat Gun R07-10300 or
equivalent. See Figure 6.

4.

Install the new blower resistor.

^

Late 1995 and 1996 Contour/Mystique: Snap the blower resistor into place.

^

1997 and 1998 Contour/Mystique: Install the retaining screw.

5.

Connect the new connector to the new resistor.

6.

Check operation of the blower motor.

7.

Install the right-hand upper foot well trim panel (if removed).