16.

Attach vent tool to vent hose from Rotunda CNG vent kit 134-00114. Refer to Figure 10.

17.

Connect vent tool (from Rotunda kit) to vent hose (from GFI kit). See Figure 10.

18.

Attach vent hose (from Rotunda kit) to venting station.

19.

Firmly secure grounding strap (from Rotunda Vent kit 134-00114) on hardline fitting (elbow where the fuel lines meet) or on the tank valve. Do
not attach to tank or non-metallic surface.

20.

Attach other end of grounding strap to a secure grounding point such as the metal support tube or metal guard posts around the venting
station.Connection must make good electrical contact.

21.

Open the quarter turn valve.

22.

Open the valve on the Rotunda Venting Tool and/or venting station.

23.

When tank is empty shut off venting station valve and/or venting station and quarter turn valve.