Safety Recall - CNG Backfire and Tank Valve Concern|Page 4663 > < Safety Recall - CNG Backfire and Tank Valve Concern|Page 4661
Page 19
background image

^

Attach shim selector template to the fuel tank collar, aligning the heavy line between the two OK's with the center of the nearest access hole on
the tank valve collar counterclockwise from the solenoid coil (located on top of the tank valve). See Figure 16.