Connect P120 to J120 at the tank valve solenoid. If Safety Recall 97S73 has been performed, the connector ends will be taped to ribbed vent
hoses.See Figure 41.

^

NOTE

The CNG fuel tank must be completely full to perform the following steps.

^

Turn off engine, switch selector to GFI position.

^

Open quarter turn valve in CNG system.

^

Start engine. Verify that the green GFI light remains illuminated.

^

Raise vehicle.

^

Leak test all connections from the intake manifold to the CNG tank, including compuvalve, regulator, filter, quarter turn valve and all fittings
using Snoop or a mild soap and water solution.