Using cable K1-124 (supplied in kit), insert one end of the cable into the RS-232 and V PWR-OUT ports of the NGS tester. Refer to Figure
39.

^

Connect other end of K1-124 to the VCL. See Figure 39.

^

Turn the switch on the cable to the OFF position.

^

Insert the power cable of the NGS tester into the vehicle's cigar lighter.

^

The NGS tester will display:

^

Using selector knob on NGS tester, select "VCL Reprogram."

^

Press the trigger button on the NGS tester.