ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Safety Recall - CNG Backfire and Tank Valve Concern|Page 4487 > < Safety Recall - CNG Backfire and Tank Valve Concern|Page 4485
Page 44
background image

43.

Attached to the VCL connector is another wiring harness with diagnostic connector J108 on the end.

^

Using cable N1-124, insert one end of the cable into the diagnostic connector J108. See Figure 40.

^

Insert the other end of the cable into the RS-232 port of the NGS tester.

^

Insert the power cable of the NGS tester into the vehicle's cigar lighter.

^

Then with Key On, Engine Off (KOEO) read the NGS tester.

^

The NGS tester will display:

^

Using the selector knob on the NGS tester, select "Recalibration".

^

Press the trigger button the NGS tester.