Contour L4-122 2.0L DOHC VIN 3 SFI (1995)
18.
Install Transmission Range Sensor Alignment Tool (T94P-70010-AH, or equivalent) on the TR sensor and align the TR sensor slots with the tool.
Tighten the TR sensor bolts to 12 N-m (106 lb.in). Refer to Figures 16 and 17.
19.
Connect the TR sensor electrical connector.
CAUTION:
USE EXTREME CARE NOT TO PLACE EXCESSIVE PRESSURE ON THE A/C LINES AND FITTINGS WHEN DISCONNECTING OR
REPOSITIONING A/C COMPONENTS. EXCESSIVE PRESSURE MAY CAUSE COMPONENT DAMAGE AND A/C SYSTEM LEAKS.