ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Recall - Engine Cooling Fan Electronic Fuse Installation|Page 2243 > < Recall - Engine Cooling Fan Electronic Fuse Installation|Page 2241
Page 10
background image

3.

Connect the electronic fuse(s) to the cooling fan motor electrical connector, then connect the harness to the fuse. Properly installed, you should
hear a "click" when the connector locking tabs engage, and the fuse(s) will rest against the cooling fan module shroud. See Figures 5, 6 and 7.

CAUTION

Do not position a tie strap around a fan blade.

4.

Secure the electronic fuse to the cooling fan shroud using the supplied tie straps. Refer to the previous illustrations for tie strap placement.

5.

Lower the vehicle (dual cooling fan applications only).

6.

Recheck cooling fan operation as outlined in the Operational Check procedure. Be sure to reconnect Connector No. 117 on cars without air
conditioning after the final inspection.

CAUTION

STOP! NO FURTHER ACTION IS REQUIRED.

2.0L Removal

NOTE:

You should perform this repair only if your inspection revealed a motor with a stamped slotted end cap which does not operates. In this situation, the
vehicle WILL NOT require electronic fuse installation.

1.

Install a memory saver, then disconnect the battery negative and positive cables.

Recall - Engine Cooling Fan Electronic Fuse Installation|Page 2243 > < Recall - Engine Cooling Fan Electronic Fuse Installation|Page 2241