ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC > < Refrigerant Oil|Capacity Specifications|Page 8143
Page 1
background image

Refrigerant Oil: Service and Repair

The A/C compressor uses a special refrigerant oil Motorcraft YN-12b or equivalent meeting Ford specification WSH-M1C231-B. This oil contains
special additives required for the A/C compressor.

It is important that only the specified type and quantity of refrigerant oil be used in the A/C compressor. If there is surplus oil in the system, too much oil
will circulate with the refrigerant, reducing the cooling capacity of the system. Too little oil will result in poor lubrication of the A/C compressor.

During A/C Compressor Replacement 
Whenever the A/C compressor is replaced and evidence of debris is present within the A/C system, the following must also be performed:
-

replace the suction accumulator/drier

-

replace the A/C evaporator core orifice

-

clean the A/C system by flushing or filtering.

NOTE:  Service A/C compressors are shipped without compressor oil.

When reinstalling the existing A/C compressor or installing a new A/C compressor, the A/C compressor must be serviced with the correct amount
of Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B as follows:
1. Obtain a clean container that can also be used as a measuring device.
2. Place the A/C clutch on the A/C compressor shaft so the shaft can be rotated.

3. Rotate the shaft by hand six to eight revolutions collecting the oil in a clean measuring device.
4. If the amount of oil drained from the old A/C compressor is between 85-142 ml (3-5 ounces), pour the same amount plus 30 ml (1 ounce) of

clean Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B into the new A/C compressor.

5. If the amount of oil that was removed from the old A/C compressor is greater than 142 ml (5 ounces), pour the same amount drained of clean

Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B into the new A/C compressor.

6. If the amount of refrigerant oil that was removed from the old A/C compressor is less than 85 ml (3 ounces), pour 85 ml (3 ounces) of clean

Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B into the new A/C compressor.

Refrigerant Pressure Sensor / Switch, HVAC > < Refrigerant Oil|Capacity Specifications|Page 8143