ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

CAT Monitor/O2 Sensor - MIL ON/Codes Stored In Memory|Page 3000 > < CAT Monitor/O2 Sensor - MIL ON/Codes Stored In Memory
Page 2
background image

1.

Disconnect the CMS sensor wire from the main wiring loom.

2.

Remove the CMS sensor from the exhaust Y-pipe assembly and discard.

3.

Remove the black spring clip from the top rib of the transmission case and install the clip on the transmission case bottommost rib. Position the
clip so the flylead retaining clip is on the topside, as shown in Figure 1.

4.

Install the L-shaped metal Clip/Bracket (W700465-S305) onto the second rib of the transmission case making sure the bracket points up, as shown
in Figure 1. Use a hammer, if necessary, but take care not to damage the bracket or transmission case.

5.

Carefully remove the connector and body wiring loom from its location on the subframe. The connector and body wiring loom are attached using a
fir tree connector. Use Clip/Connector (W700219-5300) if the original part is damaged during removal from the subframe.

6.

Insert the fir tree connector into the hole in the L-shaped metal bracket.

7.

Fold the excess body wiring loom over the top of the connector as shown in Figure 2. The wiring loom will be retained by the HEGO connector
when it is installed.