Vacuum/Pressure Pump Switch: Service and Repair

REMOVAL

1. Remove lumbar seat control switch from seat by pulling off snap-on seat regulator control switch bezel, then remove two retaining screws.
2. Disconnect front seat back pad adjusting tube and harness connector from lumbar seat control switch.
3. To remove seat control switch, use a small flat-bladed screwdriver and insert in holes on side of seat regulator control switch bezel. Depress metal

clips while pulling seat control switch from seat regulator control switch bezel.

INSTALLATION

1. Connect harness connector to seat control switch.
2. Connect front seat back pad adjusting tube to seat control switch. (Larger nipple to front seat back pad adjuster; smaller nipple to front seat back

pad adjusting pump.

3. Install lumbar seat control switch to seat with two retaining screws. Snap seat regulator control switch bezel into place.

NOTE:  The seat regulator control switch bezel is keyed and can only be installed one way.

4. Check seat for proper operation.