4. Check connecting rod side clearance using Dial Indicator with Bracketry 100-002 or equivalent. (clearance should be 0.15-0.45 mm
(0.006-0.0177 inch)). If side clearance is greater than maximum service limit of 0.50 mm (0.020 inch), replace connecting rods and/or crankshaft.
5. Install oil pump screen cover and tube.
NOTE: Install new O-ring, then start all bolts on oil pump and oil pump screen cover and tube before tightening.