Accumulator HVAC: Description and Operation

CAUTION:  Replacement of the suction accumulator/drier is necessary any time a major component of the refrigerant system is replaced. Failure to
replace the suction accumulator/drier will expose the refrigerant system to excessive moisture accumulation. A major component includes A/C condenser
core, A/C compressor, A/C evaporator core or a refrigerant hose/line. An A/C evaporator core orifice or O-ring seal is not considered a major component
but the A/C evaporator core orifice should be replaced whenever the A/C compressor is replaced for lack of performance.

In addition to the preceding condition, the suction accumulator/drier should also be replaced if one of the following conditions exist:

-

The suction accumulator/drier is perforated.

-

The refrigerant system has been opened to the atmosphere for a period of time longer than required to make a minor repair.

-

There is evidence of moisture in the system such as internal corrosion of metal refrigerant lines or the refrigerant oil is thick and dark.

NOTE:  The compressor oil from vehicles equipped with an FS-10 A/C compressor may have a dark color while maintaining a normal oil viscosity. This
is normal for this A/C compressor because carbon from the A/C compressor piston rings will discolor the oil.

When replacing the suction accumulator/drier, the procedure given here must be followed to make sure the total oil charge in the system is correct after
the new suction accumulator/drier is installed.

-

Drain the oil from the removed suction accumulator/drier into a suitable measuring container. Drill one or two 1/ 2-inch holes in the bottom of the
old suction accumulator/drier to make sure all the oil has drained out.

-

Add the same amount plus 60 ml (2 ounces) of clean, new Motorcraft YN-12c refrigerant oil meeting Ford specification WSH-M1C231-B to the
new suction accumulator/drier.