Multifunction Switch: Initial Inspection and Diagnostic Overview

NOTE:  The Rotunda New Generation Star (NGS) Tester 007-00500 or equivalent scan tool must be used to perform diagnostics. The Rotunda Service
Bay Diagnostic Systems (SBDS) 001-00001 may also be used to diagnose this system.

INSPECTION AND VERIFICATION

1. Verify the customer's concern by operating the ignition switch and multi-function switch to duplicate the condition.
2. Inspect to determine if one of the following mechanical or electrical concerns apply:

Mechanical
-

Damaged multi-function switch.

-

Damaged ignition switch.

Electrical
-

Circuitry open/shorted.

-

Open Junction Panel Fuse:
-

4 (15A)  

-

13 (15A)

-

6 (15A)  

-

1 (15A)

-

5 (15A)

-

Circuit breaker 14 (20A)

-

Open Power Distribution Box Fuse
-

IGNSW (50A)  

-

STR/ALT (30A).

3. If inspection reveals an obvious concern that is readily serviced, correct the concern before continuing with Inspection and Verification.
4. If the concern remains after inspection, connect the scan tool to the data link connector (DLC) located beneath the instrument panel to perform

DATA LINK DIAGNOSTICS (DTC) test. If the scan tool responds with NO RESPONSE/NOT EQUIPPED for the lighting control module, go to
Pinpoint Test A. 

 

If the DATA LINK DIAGNOSTICS test is passed for the lighting control module, retrieve continuous DTCs and execute Self Test Diagnostics for
the lighting control module to retrieve current DTCs.

5. If self test is passed and no DTCs are retrieved go to the Symptom Chart to continue diagnostics.

 See: Symptom Related Diagnostic Procedures

 

6. If DTCs are retrieved, go to the Lighting Control Module (LCM) Diagnostic Trouble Code (DTC) Index to continue diagnostics.

 See: Testing and Inspection/Diagnostic Trouble Code Descriptions/LCM Diagnostic Trouble Code Index

7. If the lighting control module cannot be accessed by the scan tool, go to Pinpoint Test A.

 

Multifunction Switch <--> [Turn Signal Switch]|Flow of Diagnosis|Page 10180 > < Multifunction Switch <--> [Turn Signal Switch]|Flow of Diagnosis