ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Shifter A/T > < Shift Solenoid, A/T|Service and Repair|Page 4888
Page 5
background image

9. Insert Digital Transmission Range (TR) Sensor Alignment Tool 307-351 (T97L-7001O-A) into slots. Align all three slots on digital transmission

range sensor with three tabs on tool.

10. Tighten digital TR sensor bolts to 7 - 10 Nm (62 - 88 inch lbs.).
11. Install manual control valve detent lever spring and bolt. Tighten bolt to 9 - 11 Nm (80 - 97 inch lbs.).
12. Clean, inspect and install pan to case gasket. Tighten all bolts to 12 - 15 Nm (107 - 132 inch lbs.). 

NOTE:  Transmission oil pan to case gasket is reusable if not damaged.

13. Attach transmission linkage to manual control lever. Tighten adjusting nut to 19 - 26 Nm (14 - 19 ft. lbs.).
14. Pour 4.7 liters (5 quarts) of MERCON V Automatic Transmission Fluid XT-5-QM meeting MERCON V specification fluid into oil filler tube.
15. Reconnect battery ground cable.
16. Start the engine and add specified fluid as required to achieve the proper fluid level.
17. Check the transmission for leaks.

Shifter A/T > < Shift Solenoid, A/T|Service and Repair|Page 4888