connectors and tighten the manual lock-down jackscrews to 9 Nm (80 in lbs) on the fuel tanks not to be vented The vent box on the upper fuel
tank rack will need to be removed to access the upper fuel tank rack solenoid jackscrews and individual upper fuel tank solenoid electrical
connectors. If neither of the upper fuel tanks needs to be vented, the upper fuel tank rack harness connector C421 may be disconnected without
removing the upper fuel tank rack vent box.

2. Connect the Ground Cable to the ground rod.

3. Connect the Fuel Filler Neck Venting Kit to the fuel filler valve.

NOTE:  Make sure the manual bleed valve on the Fuel Filler Neck Venting Kit is closed prior to connecting to the fuel filler valve.

4. Connect the Venting Hose Assembly to the Fuel Filler Neck Venting Kit.

5. Connect the Venting Hose Assembly to the vent stack.

Special Tools Used While Performing Procedures|Page 1991 > < Special Tools Used While Performing Procedures|Page 1989