9. Connect the LH ignition coil and fuel injector electrical connectors and the wiring harness retainers.

Romeo engine (4.6L)

10. Install the EGR valve tube.

^

Hand-tighten the upper and lower fittings.

^

Tighten to 40 Nm (30 ft. lbs.).

11. Connect the differential pressure feedback EGR sensor hoses to the EGR valve tube.