background image

Disconnect the evaporator outlet fitting.
-

Discard the O-ring seal.

Vehicles without auxiliary A/C

7. CAUTION:  Use a wrench on each side of the fitting to prevent twisting of the refrigerant line.

Disconnect the compressor manifold and tube suction fitting.
1

Remove the screw.

2

Disconnect the fitting.

-

Discard the O-ring seal.

Vehicles with auxiliary A/C

8. Remove the screw.

9. Disconnect the spring lock coupling.

-

Discard the O-ring seals.

All vehicles