Expansion Block/Orifice Tube: Description and Operation

EVAPORATOR CORE ORIFICE

NOTE:  A new evaporator core orifice should be installed whenever a new A/C compressor is installed.

The evaporator core orifice has the following characteristics:

-

It is located in the evaporator core inlet tube.

-

It has filter screens located on the inlet and outlet ends of the tube body.

-

The inlet filter screen acts as a strainer for the liquid refrigerant flowing through the A/C evaporator core orifice.

-

O-ring seals on the evaporator core orifice prevent the high-pressure liquid refrigerant from bypassing the evaporator core orifice.

-

Adjustment or service cannot be made to the evaporator core orifice assembly, a new evaporator core orifice assembly must be installed as a unit.