ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Important Information|Page 6791 > < Important Information|Page 6789
Page 3
background image

9. Scroll down to appropriate vehicle application and highlight and trigger to start the NGS.

4WABS System Bleeding

10. The NGS will prompt you to verify correct application. Trigger the.NGS if correct.

4WABS System Bleeding

11. Select DIAGNOSTIC DATA LINK and press trigger to start the NGS.

4WABS Bleeding Procedure

12. Follow the NGS prompt PRESS TRIGGER TO CONTINUE or PRESS CANCEL TO BYPASS.

4WABS Bleeding Procedure

13. Select ABS ANTI-LOCK BRAKE MODULE and press trigger to start the NGS.

4WABS Bleeding Procedure

14. Select FUNCTION TESTS and press trigger to start the NGS.

4WABS Bleeding Procedure

15. Select SERVICE BLEED FUNCTION and press trigger to start the NGS.