ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Compressor Fitting HVAC|Specifications|Page 8910 > < Compressor Fitting HVAC|Specifications|Page 8908
Page 3
background image

8. Remove the A/C manifold and tube.

a. Loosen the screw.
b. Remove the A/C manifold and tube.

INSTALLATION

1. Add new, clean Motorcraft refrigerant oil YN-12b or equivalent meeting Ford specification WSH-M1C231-B.

Note: Whenever replacing an A/C system component or refrigerant line, new, clean refrigerant oil must be added.

2. Install the A/C manifold and tube.

a. Install two new green O-rings.

Note:  The green O-ring(s) cannot be seen. They are located in the connection(s).

b. Install the A/C manifold and tube. 
c. Tighten the screw.

3. Connect the compressor discharge line.

a. Install a new green O-ring.

^

Lubricate with clean Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B.

Note:  The green O-ring(s) cannot be seen. They are located in the connection(s).

b. Connect the compressor-to-condenser core fitting.

Note:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

Compressor Fitting HVAC|Specifications|Page 8910 > < Compressor Fitting HVAC|Specifications|Page 8908