E 150 1/2 Ton Van V6-4.2L VIN 2 (1997)
Condenser HVAC: Service and Repair
REMOVAL
1. Recover the refrigerant. See: Service and Repair/Refrigerant Recovery
NOTE: Cap or plug all open refrigerant line fittings to prevent the entry of dirt and moisture.
2. Remove the air deflector.
a. Remove the five retaining pins.
b. Remove the air deflector.
3. Move the compressor discharge line isolator.
a. Remove the screw.
b. Move the compressor discharge line isolator.
4. Disconnect the condenser core refrigerant lines.