Expansion Block/Orifice Tube: Service and Repair

Special Tools

Broken Orifice Tube Extractor

Fixed Orifice Tube

REMOVAL

1. Remove condenser to evaporator tube.

CAUTION:  Do not attempt to remove the A/C evaporator core orifice with pliers or to twist or rotate the orifice in the liquid line. To do so will
break the fixed orifice tube body in the discharge line. Use only the recommended tool.

NOTE:  Replace the A/C evaporator core orifice whenever an A/C compressor is replaced for internal damage.

2. Engage the (A) Fixed Orifice Tube Remover/Replacer with the (B) two A/C evaporator core orifice tangs.