Alternator Brush: Service and Repair

REMOVAL 

1. Remove the generator.

2. Remove the generator brush and terminal holder and the voltage regulator.

1

Remove the four voltage regulator screws.

2

Remove the generator brush and terminal holder and the voltage regulator.

3. Separate the generator brush and terminal holder from the voltage regulator.

1

Remove the screw cap.

2

Remove the two generator brush and terminal holder screws.

3

Separate the generator brush and terminal holder from the voltage regulator.

INSTALLATION 

1. Install the brush and terminal holder on the voltage regulator.

1

Position the brush and terminal holder on the voltage regulator.

2

Install the two generator brush and terminal holder screws.

3

Install the screw cap.

CAUTION:  Make sure screw cap is installed over Test Terminal A to prevent accidental shorting of the battery positive connection.