ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Torque Converter|Flow of Diagnosis|Page 6003 > < Torque Converter|Flow of Diagnosis
Page 1
background image

Torque Converter: Component Tests and General Diagnostics

End Play Check

1. Insert End Play Checking Tool T80L-7902-A into the torque converter pump drive.

(1) Position End Play Checking Tool T80L-7902-A.
(2) Tighten the inner post until the tool is securely locked.

2. Attach Dial Indicator With Bracketry TOOL-4201-C to End Play Checking Tool T80L-7902-A.

-

Position the dial indicator bottom on the converter pump drive hub and zero the dial.

3. Lift up on End Play Checking Tool T80L-7902-A and note the dial indicator reading.

-

If the reading exceeds end play limits, replace the torque converter.

Torque Converter End Play 

New or Rebuilt:  0.355- 1.04 mm (0.014-0.041 inch) Max. 
Used:  0.355-1.87 mm (0.014-0.074 inch) Max. 

4. Remove the dial indicator and tool.

Leakage Checks

1. Clean the outside surface of the torque converter.

Torque Converter|Flow of Diagnosis|Page 6003 > < Torque Converter|Flow of Diagnosis