ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Pinion Gear, Differential|Testing and Inspection|Page 6247 > < Pinion Gear, Differential|Testing and Inspection|Page 6245
Page 3
background image

3. Make sure the cups are properly seated in their bores. If a 0.038 mm (0.0015 inch) feeler gauge can be inserted between a cup and the bottom of

its bore at any point around the cup, the cup is not properly seated. Whenever the cups are replaced, the pinion bearings must also be replaced.

4. Assemble and position the Pinion Depth Gauge Set.

(1) Position the Screw.
(2) Position the Aligning Adapter. 
(3) Position the Gauge Disc. 
(4) Position the Gauge Block.
(5) Position the inner pinion bearing. 
(6) Position the outer pinion bearing. 
(7) Thread on the Handle.

NOTE:Apply only a light oil film on the pinion bearings before assembling the tool. 

5. Tighten the Handle.