background image

Inspect for gaps and holes in the factory applied sealer along the outboard side of the C-channel (Figure 1) (weatherstrip is pulled out of C-channel in
Figure 1). Using a water bottle, force water into any hole to see if a leak occurs, allowing water to exit the opposite side of the C-channel. Adjust hose to
spray pattern and direct water across the rear end of the roof and at the top of the door. Inspect for water leaks. If leaks are found using either test, reseal
the entire length of each side of the C-channel to the door sheet metal using clear silicone sealant.