ford Workshop Repair Guides

Ford E 150 Van L6-300 Workshop Service and Auto Repair Manuals

A/C - Condensate Leaks Into Passenger Compartment|Page 2721 > < A/C - Condensate Leaks Into Passenger Compartment|Page 2719
Page 4
background image

Figure 24

2.

Install the new check valve and drain tube assembly and retainer (service kit D6UZ-19858-B) using the two hex head 5/8 inch long, No. 10 screws
provided (Figure 24). Note that the key tab fits into the slot towards the front of the vehicle. Two spring nuts are available in the kit, if required.

3.

Apply a liberal bead of fillet of silicone sealer to both sides of the sealing surfaces to seal any air leak paths due to housing surface irregularities.

Procedure For Inspection And Repair Of Evaporator/Blower Housing Flange And Cover Leaks Into Passenger Compartment

A/C - Condensate Leaks Into Passenger Compartment|Page 2721 > < A/C - Condensate Leaks Into Passenger Compartment|Page 2719