8. Rotate the tensioner clockwise and install the accessory drive belt onto the generator pulley.
9. Install the 8 ignition coils and the 8 bolts.

^

Tighten to 6 Nm (53 inch lbs.).

10. Connect the 8 fuel injector electrical connectors.
11. Connect the 8 coil-on-plug electrical connectors.

12. Install a new TB adapter gasket, position the TB adapter assembly and tighten the 4 bolts in 2 stages.

^

Stage 1: Tighten to 9 Nm (80 inch lbs.)

^

Stage 2: Tighten an additional 90 degrees.

13. Connect the EVAP vapor hose quick connect coupling. For additional information, refer to Fuel Delivery and Air Induction.

14. Connect the vacuum harness connector.

Intake Manifold|Removal and Installation|Page 2777 > < Intake Manifold|Removal and Installation|Page 2775