E 250 V8-4.6L VIN W (2006)
8. NOTE: If not secured within 4 minutes, the sealant must be removed and the sealing area cleaned with silicone gasket remover and metal surface
prep. Follow the directions on the packaging. Allow to dry until there is no sign of wetness, or 4 minutes, whichever is longer. Failure to follow
this procedure can cause future oil leakage.
Apply silicone gasket and sealant to the Woodruff key slot on the crankshaft pulley.
9. Using the special tool, install the crankshaft pulley.
10. Using a new crankshaft pulley bolt, install the crankshaft pulley bolt and washer. Using the special tool to hold the crankshaft pulley, tighten the
bolt in 4 stages:
^
Stage 1: Tighten to 90 Nm (66 ft. lbs.).
^
Stage 2: Loosen one full turn.
^
Stage 3: Tighten to 50 Nm (37 ft. lbs.).
^
Stage 4: Tighten an additional 90 degrees without exceeding 200 Nm (148 ft. lbs.).
11. Install a new O-ring seal, the CMP sensor and bolt.