ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Exhaust System|Muffler > < Exhaust Manifold - Inspection|Page 3061
Page 2
background image

1. CAUTION:  Do not use metal scrapers, wire brushes, power abrasive discs, or other abrasive means to clean the sealing surfaces. These may

cause scratches and gouges resulting in leak paths. Use a plastic scraper to clean the sealing surfaces.

Clean the sealing surfaces with metal surface prep.

2. NOTE:  Install a new exhaust manifold gasket.

Position the gasket and the RH exhaust manifold and tighten the nuts in the sequence shown.
^

Tighten to 25 Nm (18 ft. lbs.).

3. Position the Y-pipe flange and install the 2 nuts.

^

Tighten to 40 Nm (30 ft. lbs.).