E 250 V8-4.6L VIN W (2006)
5. Using the special tool, remove the manual valve detent lever shaft retaining pin.
6. CAUTION: Be careful not to damage the manual control lever bore.
Remove the manual control lever shaft assembly.
7. Using a suitable tool, remove the manual control lever seal and discard.
Installation
1. NOTE: Prior to installing the manual control lever seal, clean the bore opening with mineral spirits.
Using the special tool, install the manual control lever seal.
2. Loosen the 2 bolts on the transmission range sensor.