ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Description and Operation|Page 6075
Page 2
background image

4. Remove the 2 washer reservoir filler tube bolts and position the washer reservoir filler tube aside.

5. CAUTION:  Use a wrench on each side of the fitting to prevent twisting of the refrigerant line.

Disconnect the evaporator outlet fitting.
-

Discard the O-ring seal.

-

To install, tighten to 39 Nm (29 lb-ft).

6. Remove the suction accumulator outlet line bracket screw.

-

To install, tighten to 2 Nm (18 lb-in).

Vehicles without auxiliary A/C

7. Remove the suction accumulator outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (11 lb-ft).

Vehicles with auxiliary A/C

8. Disconnect the suction accumulator outlet spring lock coupling.

-

Discard the O-ring seals.

All vehicles

9. Disconnect the A/C cycling switch electrical connector.

10. Remove the 2 suction accumulator bolts.

-

To install, tighten to 14 Nm (10 lb-ft).

11. Remove the suction accumulator.
12. To install, reverse the removal procedure.

-

Install a new gasket seal and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

13. Evacuate, leak test and charge the refrigerant system.

Air Door, HVAC > < Accumulator HVAC|Description and Operation|Page 6075