E 250 V8-5.4L (2008)
7. Disconnect the blower motor resistor electrical connector.
8. Disconnect the vacuum connector and detach the wire harness pin-type retainer.
9. Remove the screws and position the wire harness aside.
10. Position the auxiliary A/C lines aside (if equipped).
1
Remove the auxiliary A/C line bracket bolt.
2
Position the auxiliary A/C lines aside.