Leak Detection Valve: Service and Repair

EVAPORATIVE EMISSION CANISTER VENT SOLENOID

REMOVAL

1. Remove the evaporative emission canister.

2. NOTE:

-

Inspect and install new O-ring seals as necessary.

-

A twisting and pulling motion is necessary to remove the evaporative emission canister vent solenoid.

Disconnect the electrical connector and the evaporative emissions hose and remove the canister vent solenoid.

INSTALLATION

1. NOTE:  Lubricate the O-ring seals with clean engine oil.

To install, reverse the removal procedure.
-

Carry out the evaporative emission system leak test.  See: Testing and Inspection/Component Tests and General Diagnostics/Evaporative
Emission System Leak Test

-

Carry out the evaporative emission repair verification drive cycle.  See: Testing and Inspection/Component Tests and General
Diagnostics/Evaporative Emission Repair Verification Drive Cycle