Fuel Gauge Module (CNG): Service and Repair

REMOVAL 

1. Disconnect the battery ground cable.

CAUTION:  Electronic modules are sensitive to static electrical charges. If exposed to these charges, damage may result.

2. Position the coolant recovery bottle aside.

1

Remove the retaining screws.

2

Position the coolant recovery bottle aside.

3. Remove the NGV module harness connector plastic shroud.

4. Disconnect the Natural Gas Vehicle (NGV) module assembly electrical connector.

1

Loosen the retaining bolt.

2

Disconnect the NGV module assembly electrical connector.