ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Fuel Line Venting|Page 4552 > < Fuel Line Venting|Page 4550
Page 2
background image

NOTE: 

-

It is recommended that venting be performed with a vent stack. Any vent stack installation must be approved by local authorities.

-

Do not vent any fuel tank unless the fuel tank or the fuel tank solenoid valve is being replaced. Unnecessary venting of good tanks can cause
damage to the fuel tank solenoid valve.

1. The following procedures are required to be used when venting fuel from the fuel tanks to remove the fuel tanks.

Solenoid - Functions Normally 

1. Connect the grounding cable to the back side of the fuel fill valve at the fuel line connection.

NOTE: 

-

Solenoid diagnostics must be completed on all tank solenoid valves prior to venting.

-

All fuel tank solenoid valves must be in the locked down position.

2. Connect the grounding cable to the ground rod.

3. Turn in the manual lockdown valve jackscrew on the fuel tank solenoid valve(s).

Fuel Line Venting|Page 4552 > < Fuel Line Venting|Page 4550