10. Disconnect the Exhaust Gas Recirculation (EGR) components.

1

Loosen the EGR valve to exhaust manifold lower fitting.

2

At the (A) EGR valve fitting, disconnect the EGR valve to the (B) EGR valve to exhaust manifold tube.

3

Disconnect the EGR transducer hoses.

4

Disconnect the EGR valve vacuum hose.

11. Disconnect the vapor management valve hose.

12. Remove the four bolts retaining the fuel injection supply manifold.