12. Place a 0.5-inch flat washer over the case converter-out fitting threads.

13. Connect the cleaner pressure line to the case converter-out fitting.

CAUTION:  Make sure the CBV is in the solvent tank before switching on the solvent pump. Also make sure the CBV fitting is pointing
downward so the solvent does not spray up out of the tank.

14. Place the CBV into the solvent tank.

15. Regulate the solvent pressure as specified. Switch on the solvent pump allowing the solvent to circulate through the CBV for 5 minutes. During

this time, cycle the solvent pump on and off to help dislodge contaminants.

CAUTION:  The solvent pressure must be at least 344.75 kPa (50 psi) (minimum) to overcome the valve inside the CBV and let the solvent pass
through it. Do not, however, exceed 620.5S kPa (90 psi) (maximum) solvent pressure.

16. Disconnect the cleaner pressure line from the case converter-out fitting. Remove the 0.5-inch washer.

Flushing and Cleaning|Page 5637 > < Flushing and Cleaning