ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Torque Converter|Flow of Diagnosis|Page 5839 > < Torque Converter|Flow of Diagnosis|Page 5837
Page 3
background image

3. Install the torque converter with the installed leak check tool into the press.

4. Secure the press. Apply enough force from the press to seal the tool into the torque converter.

WARNING:  Always follow proper safety procedures while using the press. 

5. Apply a maximum of 80 psi air pressure to the valve on the leak check tool.

NOTE:  Use clean, dry shop air.

6. With air pressure applied to the valve, inspect for leaks at the studs, the seams and the pilot hub. A soap bubble solution can be applied around

those areas to aid in the diagnosis. If leaks are present, replace the converter.

7. Remove the air hose. Release the pressure, and then slowly release the press.

Torque Converter|Flow of Diagnosis|Page 5839 > < Torque Converter|Flow of Diagnosis|Page 5837