17. Using 344.75-620.55 kPa (50-90 psi) of regulated compressed air, blow through the CBV until all solvent is removed.

18. Remove the plug from the CBV converter-out-to-cooler inlet.

19. Inspect the Viton-coated washers for damage. Replace as required.

20. Apply sealer to case inlet and outlet fitting threads

-

Use Thread lock and Sealer EOAZ-1955AA or equivalent meeting Ford specification WSK-M2G315-AS.

CAUTION:  Make sure the four Viton-coated washers are placed on the CBV fittings properly.