ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Heater Hose > < Heater Core - Leakage Diagnostic Tips|Page 1792
Page 2
background image

2.

Disconnect electrical connector from resistor on front of air conditioner blower scroll cover.

3.

Disconnect vacuum hose from outside recirculated door vacuum motor.

4.

Remove air conditioner blower cover attaching screws and the cover.

5.

Remove outside-recirculated door shaft push nut and washer.

6.

Remove control cable attaching screw and slide cable over bracket.

7.

Remove cable clip or wire loop from blend door shaft.

8.

Remove 9 air conditioner blower motor housing attaching screws and the housing.

9.

Remove 3 blend door housing attaching screws and the housing.

10.

Drain cooling system, then disconnect hoses from heater core.

11.

Remove 2 heater core retaining bracket attaching screws and the bracket.

12.

Remove heater core and seal assembly.

13.

Reverse procedure to install.

Heater Hose > < Heater Core - Leakage Diagnostic Tips|Page 1792