A/C Condenser Outlet Tube - Refrigerant Leak

Article No.

AIR CONDITIONING - LEAKS REFRIGERANT -

87-20-19

CONDENSER OUTLET TUBE CRACKED

LIGHT TRUCK:

1984-87 ECONOLINE

ISSUE:

Refrigerant leaks at the condenser outlet tube to the receiver/drier fitting may be caused by a fitting that was overtightened during production.
The overtightening of the fitting may cause the condenser outlet tube to crack.

ACTION:

To correct this, install a new condenser outlet tube. Torque the outlet tube to receiver/drier fitting to 5-10 ft.lbs. (7-13 N-m).

NOTE:

It is not necessary to replace the condenser assembly.

PART NUMBER

PART NAME

CLASS

E4UZ-19835-A

Condenser Outlet Tube

B

OTHER APPLICABLE ARTICLES: None
WARRANTY STATUS: Eligible Under Basic Warranty Coverage
OPERATION: SP872019A
TIME:

0.9 Hr. DLR. CODING: Basic Part No. 19835 - Code: 01