E 350 V10-6.8L (2007)
D5
Normal Operation
The VSM communicates with the scan tool through the medium speed controller area network (MS-CAN). Circuits 2180 (WH/BK) (MS-CAN +) and
2181 (BK/YE) (MS-CAN -) provide the network connection to the VSM. The VSM shares the MS-CAN network with the instrument cluster. Voltage
for the VSM is provided by circuit 517 (BK/WH). Circuits 57 (BK) and 1205 (BK) provide ground.
Possible Causes
-
Fuse
-
Circuit 57 (BK) open
-
Circuit 517 (BK/WH) open
-
Circuit 1205 (BK) open
-
Circuit 2180 (WH/BK) open (MS-CAN +)
-
Circuit 2181 (BK/YE) open (MS-CAN -)
-
VSM
Test E: The Restraints Control Module (RCM) Does Not Respond To the Scan Tool
PINPOINT TEST E: THE RESTRAINTS CONTROL MODULE (RCM) DOES NOT RESPOND TO THE SCAN TOOL