ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 9731 > < Initial Inspection and Diagnostic Overview|Page 9729
Page 5
background image

G10-G12

Normal Operation

When the brake pedal is applied, the stoplamp switch routes voltage through circuit 569 (DG) to the brake shift interlock actuator, the anti-lock brake
system (ABS) module, the powertrain control module (PCM), and the central junction box (CJB) fuse 39 (10A). The CJB then routes the voltage
through circuit 511 (LG) to the high mounted stoplamp, the trailer tow electric brake controller (if equipped), and the multifunction switch. The
multifunction switch then routes voltage to the rear lamps through circuit 9 (LG/OG) (LH rear lamp) and circuit 5 (OG/LB) (RH rear lamp).

Possible Causes

-

Circuit 5 (OG/LB) short to voltage

-

Circuit 9 (LG/OG) short to voltage

-

Circuit 511 (LG) short to voltage

-

Circuit 569 (DG) short to voltage

-

Circuit 1651 (WH/RD) short to ground

-

Stoplamp switch

-

Stability assist stoplamp control relay

-

Multifunction switch

-

Trailer tow electric brake controller

-

Brake shift interlock actuator

-

ABS module

-

PCM