ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

TorqShift|Page 4789 > < TorqShift|Page 4787
Page 6
background image

4. CAUTION:  The transmission cooler lines must be disconnected prior to flushing out the cooler lines.

Disconnect the four transmission fluid cooler lines at the remote filter housing.

5. Leave the transmission fluid cooler lines disconnected from the transmission case.
6. Disconnect both transmission fluid cooler lines from the OTA.
7. Discard the OTA if overhauling or installing a new transmission.
8. Flush each transmission fluid cooler line independently.
9. Connect the cleaner pressure and return lines correctly.

1. Connect the pressure line-to-fluid cooler inlet tube.
2. Connect the return line-to-fluid cooler outlet tube.
3. Place the outlet end of the return line in the fluid tank reservoir.

10. NOTE:  Cycling the solvent pump on and off will help dislodge contaminants in the cooler system.

Switch the pumps on. Allow the fluid to circulate a minimum of 5 minutes.

11. Switch the pump off.
12. Disconnect the cleaner pressure line at the fluid cooler tube.
13. Using compressed air, blow through the fluid cooler inlet tube until all fluid is removed.
14. Remove the rubber hoses from fluid cooler tubes.
15. Connect the cleaner pressure and return lines correctly.

1. Connect the pressure line to the radiator in-tank fluid cooler.
2. Connect the return line to the other side of the radiator in-tank fluid cooler.
3. Place the outlet end of the return line in the fluid tank reservoir.

16. NOTE:  Cycling the pump on and off will help dislodge contaminants in the cooler system.

Switch the pumps on. Allow the fluid to circulate a minimum of five minutes.

17. Switch the pump off.
18. Disconnect the cleaner pressure line at the fluid cooler tube.
19. Using compressed air, blow through the fluid cooler inlet tube until all fluid is removed.
20. Remove the rubber hoses from fluid cooler tubes.
21. Flush the remote filter manifold and make sure that the small bypass orifice is free of foreign material.
22. Flush the remote filter housing and clean the magnet.
23. Backflush and then flush the radiator in-tank cooler.
24. Install a new remote filter element.
25. Install a new OTA as part of a transmission service or installing a remanufactured transmission.
26. Carry out the transmission fluid cooler flow test.

TorqShift|Page 4789 > < TorqShift|Page 4787