I12-I14

Normal Operation

The MS-CAN uses an unshielded twisted pair cable, circuits 2180 (WH/BK) and 2181 (BK/YE). The vehicle security module (VSM) and the
instrument cluster communicate with the scan tool using the MS-CAN network.

Possible Causes

-

Circuit 2180 (WH/BK) open, short to ground or voltage (MS-CAN +)

-

Circuit 2181 (BK/YE) open, short to ground or voltage (MS-CAN -)

-

Circuit 2180 (WH/BK) (MS-CAN +) and circuit 2181 (BK/YE) (MS-CAN -) shorted together

-

VSM

-

Instrument cluster

Test J: No Power To the Scan Tool

PINPOINT TEST J: NO POWER TO THE SCAN TOOL