E 350 V8-6.0L DSL Turbo VIN P (2004)
4. Disconnect the coolant hoses from the air cleaner outlet pipe.
5. NOTE: Air cleaner side shown, engine side similar.
Loosen the clamps and remove the air cleaner outlet pipe.
Number 1, 3-8 glow plugs
6. Remove the engine cover.
All glow plugs
7. CAUTION: Do not pull on the wiring to remove the glow plug connector or damage may occur.
NOTE:
-
Only one glow plug connector shown.
-
Only the number 2 glow plug is accessed from under the hood, all others are accessed from inside the cab.
Remove the glow plug harness as needed.