ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Standard A/C|Page 8340 > < Accumulator HVAC|Specifications|Page 8337
Page 1
background image

Accumulator HVAC: Service and Repair
Standard A/C

REMOVAL

1. Recover the refrigerant. See: Service and Repair/Refrigerant Recovery

CAUTION:  The suction accumulator/drier must be replaced whenever the A/C compressor, other major A/C components, or a refrigerant line is
being replaced due to failure.

NOTE:  Cap or plug all open refrigerant line fittings to prevent entry of dirt and moisture.

2. Remove the battery.

WARNING:  TO AVOID ACCIDENTAL DEPLOYMENT AND POSSIBLE INJURY, THE AIR BAG SYSTEM BACKUP POWER
SUPPLY MUST BE DEPLETED BEFORE REPAIRING ANY CLIMATE CONTROL COMPONENTS. TO DEPLETE THE BACKUP
POWER SUPPLY, DISCONNECT THE BATTERY TO STARTER CABLE AND WAIT ONE MINUTE.

3. Remove the battery tray.

a. Remove the screws.
b. Remove the battery tray.

4. Disconnect the evaporator discharge line.

NOTE:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

5. Disconnect the compressor suction line.

a. Remove the screw.
b. Disconnect the compressor suction line.

Standard A/C|Page 8340 > < Accumulator HVAC|Specifications|Page 8337