ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

All Technical Service Bulletins for Blower Motor Switch: > < Auxiliary Blower Relay|Page 3714
Page 1
background image

Blower Motor Switch: Customer Interest
Blower Motor - Inoperative

Article No. 
91-11-17

05/30/91

^

HEATER - BLOWER MOTOR INOPERATIVE

^

HEATER - BLOWER SWITCH - OVERHEATS AND BECOMES INOPERATIVE

LIGHT TRUCK:

1988-89 ECONOLINE

ISSUE:

The heater blower motor may become inoperative. This can occur if the main heater blower motor switch overheats and becomes inoperative.

ACTION:

Install a new heater blower motor switch. Refer to the following procedure for service details.

1.

Remove the blower motor switch. Refer to the 1988/89 Econoline Shop Manual, Section 36-23, for removal procedure.

2.

Cut the wires leading to the damaged heater blower switch connector and discard the connector.

3.

If the heater switch blower switch is damaged, replace it with a new switch (D5AZ-19986-A).

4.

Splice together the wires cut in Step # 2 with the appropriate pigtail wires on the jumper harness (F1UZ-18C629-A); a connector and 4 terminals
with pigtails).

5.

Attach the new connector to the switch.

6.

Install the blower switch. Refer to the 1988/89 Econoline Shop Manual, Section 36-23, for service details.

CAUTION: TO ENSURE PROPER CONNECTION BETWEEN THE SWITCH TERMINALS AND THE CONNECTOR, MAKE SURE THAT

THE CONNECTOR IS FULLY ENGAGED AND IN THE LOCKED POSITION. DO NOT USE A FILLER MATERIAL TO TIGHTEN
THE CONNECTION BECAUSE THESE MATERIALS MAY CAUSE FURTHER OVERHEATING CONCERNS WITH THIS
CONNECTION.

PART NUMBER

PART NAME

CLASS

F1UZ-18C629-A

Heater Blower Switch Jumper

B

Harness

D5AZ-19986-A

Heater Blower Switch

A

OTHER APPLICABLE ARTICLES: NONE
WARRANTY STATUS: Eligible Under Basic Warranty 

Coverage

OPERATION DESCRIPTION

TIME

911117A

Install Heater Blower Motor

0.6 Hr.

Switch

DEALER CODING 

BASIC PART NO.

CONDITION CODE

19986

65

OASIS CODES:

208000, 208100

All Technical Service Bulletins for Blower Motor Switch: > < Auxiliary Blower Relay|Page 3714